Evaluation of the Bruker® MBT Sepsityper IVD module for the identification of polymicrobial blood cultures with MALDI-TOF MS

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) considerably reduces timeframe required from initial blood culture positivity towards complete bacterial identification. However, rapid identification of polymicrobial blood cultures remains challenging. We e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of clinical microbiology & infectious diseases 2018-11, Vol.37 (11), p.2145-2152
Hauptverfasser: Scohy, Anaïs, Noël, Audrey, Boeras, Anca, Brassinne, Laetitia, Laurent, Terry, Rodriguez-Villalobos, Hector, Verroken, Alexia
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) considerably reduces timeframe required from initial blood culture positivity towards complete bacterial identification. However, rapid identification of polymicrobial blood cultures remains challenging. We evaluated the performances of the Bruker® MBT Sepsityper IVD module on MALDI-TOF MS for the direct identification of polymicrobial blood culture bottles. This module has the ability to give a strong indication that a sample contains a mixture of organisms and to identify two of them. Blood culture bottles considered as polymicrobial using routine subculture were collected and processed using the Sepsityper kit. MALDI-TOF MS identification was performed using the MBT Compass IVD software including the Sepsityper module. From 143 polymicrobial blood culture bottles tested, 34.3% (49/143) were completely identified by the module. Both microorganisms were more easily detected by the module in samples containing two pathogens than in samples containing two contaminants (36.8% vs 29.4%). Additionally, in more than half of the samples, the module detected 1 of the different microorganisms contained in the same vial. In these cases, with a pathogen and contaminant in the same sample, the module detected the pathogen in more than 80%. The Sepsityper module identified 14 microorganisms which were not recovered by conventional culture methods. The Bruker® MBT Sepsityper IVD module contributed to a valuable identification of polymicrobial blood cultures in more than a third of all cases. Conventional culture methods are still required to complete the results and to carry on susceptibility testing.
ISSN:0934-9723
1435-4373
DOI:10.1007/s10096-018-3351-2