Resonance light scattering aptasensor for urinary 8-hydroxy-2′-deoxyguanosine based on magnetic nanoparticles: a preliminary study of oxidative stress association with air pollution

An aptamer based method is described for the determination of 8-hydroxy-2′-deoxyguanosine (8-OHdG) using resonance light scattering (RLS). Magnetic nanoparticles (MNPs) were employed as RLS probes. The probe DNA was placed on the surface of MNPs, which produces a rather low RLS signal. If, however,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Mikrochimica acta (1966) 2018-09, Vol.185 (9), p.419-7, Article 419
Hauptverfasser: Tao, Lixia, Yue, Qiaoli, Hou, Yining, Wang, Yongping, Chen, Chunying, Li, Chen-Zhong
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An aptamer based method is described for the determination of 8-hydroxy-2′-deoxyguanosine (8-OHdG) using resonance light scattering (RLS). Magnetic nanoparticles (MNPs) were employed as RLS probes. The probe DNA was placed on the surface of MNPs, which produces a rather low RLS signal. If, however, probe DNA hybridizes with the aptamer against 8-OHdG, a sandwich structure will be formed. This results in a significant enhancement of RLS intensity. The aptamer was used as the recognition element to capture 8-OHdG. 8-OHdG has a stronger affinity for the aptamer than probe DNA, and the conformation of the aptamer therefore switches from a double-stranded to a G-quadruplex structure. As a result, MNPs labeled with probe DNA are released, and RLS intensity decreases. The method allows 8-OHdG to be detected with a linear response in the 32 pM − 12.0 nM concentration range and an 11 pM limit of detection (at 3.29 S B / m , according to the recent recommendation of IUPAC). The MNPs can be reused 5 times by applying an external magnetic field for collection. The method was successfully applied to analyze human urine samples for its content of 8-OHdG. It was also found that the levels of 8-OHdG noticeably increased with the increase of the Air Quality Index. Conceivably, the method is a viable tool to investigate the relationship between 8-OHdG levels and the effect of air pollution. Graphical abstract A reusable sensing strategy was constructed to detect urinary 8-OHdG based on “turn-off” resonance light scattering. The LOD was as low as 11 pM. This study showed some preliminary data for the association between oxidative stress and air pollution.
ISSN:0026-3672
1436-5073
DOI:10.1007/s00604-018-2937-9