Outcomes of Stentless Thoracic Endovascular Aortic Repair for Chronic DeBakey IIIb Aneurysms

We introduce a new endovascular procedure for favorable aortic remodeling in patients with chronic DeBakey IIIb (CDIIIb) aneurysms and present outcomes. This study included 19 patients who underwent stentless thoracic endovascular aortic repair (TEVAR) for CDIIIb aneurysms between 2014 and 2016. Ste...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2018-11, Vol.106 (5), p.1308-1315
Hauptverfasser: Kim, Tae-Hoon, Song, Suk-Won, Lee, Kwang-Hun, Heo, Woon, Baek, Min-Young, Yoo, Kyung-Jong, Cho, Bum-Koo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We introduce a new endovascular procedure for favorable aortic remodeling in patients with chronic DeBakey IIIb (CDIIIb) aneurysms and present outcomes. This study included 19 patients who underwent stentless thoracic endovascular aortic repair (TEVAR) for CDIIIb aneurysms between 2014 and 2016. Stentless TEVAR is defined as an endovascular procedure involving closure of communicating channels or obliteration of the false lumen itself using various materials. Thoracic false lumen thrombosis was defined as there was no flow in the false lumen of the thoracic aorta. Aortic diameter was measured at 3 levels (left subclavian artery, pulmonary artery bifurcation, and celiac axis). Fifteen of 19 (78.9%) patients demonstrated thoracic false lumen thrombosis. There was no mortality, and the mean follow-up duration was 16.8 months. False and true lumen diameters at the left subclavian and pulmonary artery levels significantly changed after the procedure (false lumen: 22.6 ± 16.6 versus 16.1 ± 14.4 mm, 23.2 ± 14.6 versus 18.0 ± 13.2 mm, p = 0.001 and p = 0.002, respectively; true lumen: 22.7 ± 8.7 versus 27.9 ± 6.3 mm, 19.0 ± 8.3 versus 24.3 ± 6.7 mm, p = 0.001 and p = 0.001, respectively). The number of visceral stent grafts and preoperative true lumen diameter at the pulmonary artery were independent predictors for thoracic false lumen thrombosis (hazard ratio, 3.445, 95% confidence interval, 1.494 to 7.946; p = 0.004; and hazard ratio, 1.106; 95% confidence interval, 1.029 to 1.189; p = 0.006, respectively). Stentless TEVAR seems to be a safe procedure and enables favorable aortic remodeling. Thus, this technique can be useful in a selected group of patients with CDIIIb aneurysms.
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2018.06.057