Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery

To investigate the effects of cataract surgery on corneal biomechanics and intraocular pressure (IOP) measured with the updated Corvis ST tonometer (CST). Prospective, interventional case series study. This study included 39 eyes of 39 cataract patients. CST measurements were performed at presurgery...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of ophthalmology 2018-11, Vol.195, p.26-35
Hauptverfasser: Hirasawa, Kazunori, Nakakura, Shunsuke, Nakao, Yoshitaka, Fujino, Yuri, Matsuura, Masato, Murata, Hiroshi, Kiuchi, Yoshiaki, Asaoka, Ryo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:To investigate the effects of cataract surgery on corneal biomechanics and intraocular pressure (IOP) measured with the updated Corvis ST tonometer (CST). Prospective, interventional case series study. This study included 39 eyes of 39 cataract patients. CST measurements were performed at presurgery (Pre) as well as 1 week (1W), 1 month (1M), and 3 months (3M) postsurgery. The following CST parameters were recorded: deformation amplitude max (DA max), DA ratio max 1 mm and 2 mm, integrated radius, stiffness parameter at applanation 1 (SP A1), Ambrosio relational thickness to the horizontal profile (ARTh), Corvis biomechanical index (CBI), central corneal thickness (CCT), noncorrected intraocular pressure (IOPnct), and biomechanically corrected IOP (bIOP). IOP was also measured with Goldmann applanation tonometry and the noncontact tonometer CT-90A. All measurements were compared at each period using the linear mixed model, with and without adjustment for bIOP and CCT. All IOP measurements decreased over time (P < .01). CCT was increased at 1W and 3M (P < .01), whereas ARTh was decreased at 1W and 1M (P < .01), but returned to its Pre level at 3M. DA max and Integrated radius were increased at 3M (P < .01), whereas SP A1 was decreased at 3M (P < .01). CBI was increased at 1W (P < .01), but returned to its Pre level at 1M. IOP and Corneal biomechanical properties are changed after cataract surgery. In particular, SP A1 decreases while DA max and integrated radius increase, even at 3M, suggesting a less stiff cornea. •Corvis ST measured changes in corneal biomechanical properties after cataract surgery.•Stiffness parameter at applanation 1 decreases while maximum deformation amplitude and integrated radius increase after cataract surgery.•These changes suggest a less stiff cornea after cataract surgery.•Goldmann applanation tonometry–measured intraocular pressure was deceased.•Corvis ST's biomechanically corrected intraocular pressure was also decreased.
ISSN:0002-9394
1879-1891
DOI:10.1016/j.ajo.2018.07.025