Mitochondrial Multiplex Real-Time PCR as a Source Tracking Method in Fecal-Contaminated Effluents

Multiplex real-time PCR amplifying fecal mitochondrial DNA (mtDNA) combined with rapid, crude DNA preparations are promising additions to surface water source tracking methods. Amplification of eukaryotic mitochondrial DNA identifies the fecal source directly and can be used in conjunction with othe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environmental science & technology 2007-05, Vol.41 (9), p.3277-3283
Hauptverfasser: Caldwell, Jane M, Raley, Morgan E, Levine, Jay F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Multiplex real-time PCR amplifying fecal mitochondrial DNA (mtDNA) combined with rapid, crude DNA preparations are promising additions to surface water source tracking methods. Amplification of eukaryotic mitochondrial DNA identifies the fecal source directly and can be used in conjunction with other intestinal microbial methods to characterize effluents. Species-specific primers and dual-labeled probes for human, swine, and bovine NADH dehydrogenase subunit 5 (ND5) genes were created for multiplex real-time PCR in feces and effluent slurries. The linear range of the multiplex assay was 102−107 mtDNA copies for human, bovine, and swine effluent in combination (equal volumes). PCR amplification efficiencies for bovine, human, and swine mtDNA when assayed in combination were 93, 107, and 92% respectively. Linear regression correlation coefficients (r 2) were 0.99 for all standard curves except for human mtDNA in combination (r 2 = 0.95). Multiplex amplification of bovine, human, and swine mtDNA (ND5) exhibited no cross-reactions between the effluents from three species of interest. Also, no cross-reactions were observed with effluents of other vertebrates:  sheep, goat, horse, dog, cat, Canada goose, broiler, layer, turkey, and tilapia. Performed as a blind test, the PCR operator was able to correctly identify all but two effluent challenge samples (10/12 or 83% correct) with no false positives (22/22 or 100% correct). The multiplex assay had a tendency to detect the species of highest mtDNA concentration only. Better detection of all three species in a combination of human, bovine, and swine effluents was accomplished by running each real-time PCR primer/probe set singly. Real-time PCR detection limit was calculated as 2.0 × 106 mitochondrial copies or 0.2 g of human feces per 100 mL effluent. Some carry-over mtDNA PCR signal from consumed beef, but not pork, was found in feces of human volunteers.
ISSN:0013-936X
1520-5851
DOI:10.1021/es062912s