Avoiding hypoglycemia: the use of insulin pump combined with continuous glucose monitor in type 1 diabetes crossing a Rocky Gorge

Continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring systems (CGMS) have been proven very effective in diabetes management. This study evaluated the usefulness of these devices during prolonged, intense physical activity in an uncontrolled natural environment away from t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:QJM : An International Journal of Medicine 2018-09, Vol.111 (9), p.629-633
Hauptverfasser: Thomakos, P, Vazeou, A, Sakkas, D, Panagopoulos, G, Anifantakis, K, Smyrnaki, P, Arvanitaki, T, Kyrlaki, E, Kefalogiannis, N, Mamoulakis, D, Pappas, A, Mitrakou, A
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring systems (CGMS) have been proven very effective in diabetes management. This study evaluated the usefulness of these devices during prolonged, intense physical activity in an uncontrolled natural environment away from the clinical research center. Non-randomized, prospective and observational study. During the summer, 38 participants with type 1 diabetes crossed the Samaria gorge, the second largest gorge in Europe (17 km). Twenty subjects on CSII combined with real-time CGMS and 18 on multiple daily injections (MDI) combined with professional (retrospective) CGMS participated in the program. All participants were unsupervised during the event. All 38 participants managed to reach the destination point safely. There were no episodes of severe hypoglycemia. The duration of the exercise (mean ±SD) was 6.4 ± 1.3 h. The CSII group exhibited significantly lower hypoglycemic episodes during exercise (0.1 ± 0.3 vs. 0.4 ± 0.6; P = 0.047) as well as lower AUC below 70 mg/dl compared with the MDI, during the 24 h (0.61 ± 0.78 vs. 1.84 ± 1.55; P = 0.007). Individuals on CSII were significantly less likely to develop a hypoglycemic episode during exercise (P = 0.038). Exercise induced nocturnal hypoglycemia was not prevented effectively in neither group. CSII combined with CGMS is effective in controlling blood glucose levels in type 1 diabetics who perform prolonged strenuous exercise. The use of insulin pump technology in regions with hot Mediterranean climates is safe and can provide protection against exercise-induced hypoglycemia. Development of precise instructions for T1DM who occasionally get involved in exercise activities, requires further studies.
ISSN:1460-2725
1460-2393
DOI:10.1093/qjmed/hcy136