Accuracy of powered surgical instruments compared with manual instruments for pedicle screw insertion: Evaluation using o-arm-based navigation in scoliosis surgery
Though powered surgical instruments for pedicle screw insertion combined with navigation have been developed to reduce time taken for spine surgery, clinical evidence demonstrating the safety and effectiveness of powered surgical instruments is limited. The goals of the present study were to compare...
Gespeichert in:
Veröffentlicht in: | Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association 2018-09, Vol.23 (5), p.765-769 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Though powered surgical instruments for pedicle screw insertion combined with navigation have been developed to reduce time taken for spine surgery, clinical evidence demonstrating the safety and effectiveness of powered surgical instruments is limited. The goals of the present study were to compare the accuracy of powered instruments and manual instruments using O-arm-based navigation in surgery for scoliosis.
We retrospectively identified 60 consecutive patients with adolescent idiopathic scoliosis who underwent posterior corrective surgery using O-arm based navigation, collected from Jun 2013 to Feb 2015. Overall, 393 screws were tapped and inserted in 30 patients using manual instruments (group M) and 547 screws were tapped and inserted in 30 patients using powered instruments (group P). Postoperative computed tomography was used to assess screw accuracy using the established Neo classification (Grade 0, no perforation; Grade 1, perforation |
---|---|