Temporal analysis of the interference caused by paratuberculosis vaccination on the tuberculosis diagnostic tests in goats
•Paratuberculosis vaccination interferes with the diagnosis of tuberculosis.•The interference on the cellular-based diagnostic tests decreases over time.•Consecutive intradermal tests in paratuberculosis vaccinated animals increases the interference on antibody-based diagnostic tests.•Results are us...
Gespeichert in:
Veröffentlicht in: | Preventive veterinary medicine 2018-08, Vol.156, p.68-75 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Paratuberculosis vaccination interferes with the diagnosis of tuberculosis.•The interference on the cellular-based diagnostic tests decreases over time.•Consecutive intradermal tests in paratuberculosis vaccinated animals increases the interference on antibody-based diagnostic tests.•Results are useful for the design of tuberculosis eradication programs.
Vaccination against paratuberculosis (PTB) in goats is a cost-effective control strategy, and is also effective as regards preventing the onset of clinical cases. However, it causes interference in the diagnostic tests used in the control of tuberculosis (TB). A group of 99 goats from a herd with no history of TB or PTB infection was vaccinated against PTB at seven months of age. They then underwent consecutive intradermal tests [single (SIT) and comparative (CIT) intradermal tuberculin tests), interferon-gamma release assays (IGRA) and two serological tests (p22_CE and DR-ELISA) every three months, until the interference disappeared. When using the SIT test, a variable number of positive reactors were observed at 3 months (T3; 32.3%, 95% CI 23.9–42.1), 6 months (T6; 11.5%, 95% CI 6.5–19.4), 9 months (T9; 6.4%, 95% CI 3.0–13.2) and 12 months (T12; 0%, 95% CI 0–4.0) post-vaccination. In contrast, the CIT test had a specificity (Sp) of 100% (95%, CI 96.0–100, regardless of the time post-vaccination. The IGRA also obtained high Sp values throughout the study period. No significant interference in the serological tests was recorded at T3 [p22_CE, Sp = 96% (95% CI 90.1–98.4) and DR-ELISA, Sp = 98% (95% CI 92.9–99.4)], although an increase in antibody titers was observed in the following herd testing events. In conclusion, the use of the SIT test causes the onset of false-positive reactors if applied before 12 months post-vaccination in a TB-free/PTB-vaccinated herd. Nevertheless, the CIT test and IGRA obtained high Sp values under these epidemiological circumstances. The serological tests were also highly specific in the case of PTB-vaccinated goats, although their Sp decreased significantly after several intradermal tests. |
---|---|
ISSN: | 0167-5877 1873-1716 |
DOI: | 10.1016/j.prevetmed.2018.05.010 |