Determination of ultra-low level plutonium isotopes (239Pu, 240Pu) in environmental samples with high uranium

In order to measure trace plutonium and its isotopes ratio (240Pu/239Pu) in environmental samples with a high uranium, an analytical method was developed using radiochemical separation for separation of plutonium from matrix and interfering elements including most of uranium and ICP-MS for measureme...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Talanta (Oxford) 2018-09, Vol.187, p.357-364
Hauptverfasser: Xing, Shan, Zhang, Weichao, Qiao, Jixin, Hou, Xiaolin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In order to measure trace plutonium and its isotopes ratio (240Pu/239Pu) in environmental samples with a high uranium, an analytical method was developed using radiochemical separation for separation of plutonium from matrix and interfering elements including most of uranium and ICP-MS for measurement of plutonium isotopes. A novel measurement method was established for extensively removing the isobaric interference from uranium (238U1H and 238UH2+) and tailing of 238U, but significantly improving the measurement sensitivity of plutonium isotopes by employing NH3/He as collision/reaction cell gases and MS/MS system in the triple quadrupole ICP-MS instrument. The results show that removal efficiency of uranium interference was improved by more than 15 times, and the sensitivity of plutonium isotopes was increased by a factor of more than 3 compared to the conventional ICP-MS. The mechanism on the effective suppress of 238U interference for 239Pu measurement using NH3-He reaction gases was explored to be the formation of UNH+ and UNH2+ in the reactions of UH+ and U+ with NH3, while no reaction between NH3 and Pu+. The detection limits of this method were estimated to be 0.55 fg mL-1 for 239Pu, 0.09 fg mL−1 for 240Pu. The analytical precision and accuracy of the method for Pu isotopes concentration and 240Pu/239Pu atomic ratio were evaluated by analysis of sediment reference materials (IAEA-385 and IAEA-412) with different levels of plutonium and uranium. The developed method were successfully applied to determine 239Pu and 240Pu concentrations and 240Pu/239Pu atomic ratios in soil samples collected in coastal areas of eastern China. [Display omitted] •ICP-MS/MS using NH3/He gasses was first utilized to measure Pu isotopes with a high uranium.•The interferences of uranium was suppressed by more than 2 orders of magnitude compared to conventional ICP-MS.•The detection limits were estimated to be 0.55 fg mL1 for 239Pu, 0.09 fg mL−1 for 240Pu.•239+240Pu activities (0.011–0.27 mBq g−1) and 240Pu/239Pu atomic ratios (0.16–0.22) indicate a global atmospheric fallout source in the coastal area of eastern China.
ISSN:0039-9140
1873-3573
DOI:10.1016/j.talanta.2018.05.051