Strategic Use of Immunoprecipitation and LC/MS/MS for Trace-Level Protein Quantification: Myosin Light Chain 1, a Biomarker of Cardiac Necrosis
Myosin light chain 1 (Myl3) is a 23-kDa isoform of one of the subunits of myosin, a protein involved in muscle contraction. Myl3 is presently being studied as a biomarker of cardiac necrosis to predict drug-induced cardiotoxicity, and in the work presented here, an LC/MS/MS assay was developed and v...
Gespeichert in:
Veröffentlicht in: | Analytical chemistry (Washington) 2007-06, Vol.79 (11), p.4199-4205 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Myosin light chain 1 (Myl3) is a 23-kDa isoform of one of the subunits of myosin, a protein involved in muscle contraction. Myl3 is presently being studied as a biomarker of cardiac necrosis to predict drug-induced cardiotoxicity, and in the work presented here, an LC/MS/MS assay was developed and validated to measure Myl3 in rat serum. The key steps in this approach involved immunoaffinity purification of Myl3 from serum followed by on-bead digestion with trypsin to release a surrogate peptide. This tryptic peptide was quantified using a synthetic peptide standard and a corresponding stable isotope-labeled internal standard, and the results were stoichiometrically converted to Myl3 serum concentrations. Myl3 concentrations were corrected for peptide recovery following immunoprecipitation and digestion (85%) and showed excellent agreement with synthetic peptide standards. Both the synthetic peptide and His-Myl3 protein were used to evaluate assay accuracy (% RE) and precision (% CV), which were measured on each of 3 days. The synthetic peptide was evaluated over the range of 0.073−7.16 nM, while Myl3 protein QC samples prepared in rat serum were evaluated over the range of 0.13−6.62 nM. To prepare control matrix, endogenous Myl3 was immunodepleted from pooled rat serum. Peptide interday accuracy and precision did not exceed 7.6 and 11.1%, and Myl3 interday accuracy and precision did not exceed 12.9 and 13.2%, respectively. Data are presented from the application of this assay to establish a time course in which rats demonstrated a marked increase in Myl3 serum concentrations following administration of isoproterenol, a β-adrenergic receptor agonist known to induce cardiac injury. This assay is an example of a larger effort in our laboratory to use LC/MS/MS in conjunction with immunoaffinity techniques to evaluate candidate biomarkers of target organ toxicity and to expedite the development of biomarker assays for drug development. |
---|---|
ISSN: | 0003-2700 1520-6882 |
DOI: | 10.1021/ac070051f |