Simultaneous determination of 22 volatile organic compounds, methyl- tert-butyl ether, 1,4-dioxane, 2-methylisoborneol and geosmin in water by headspace solid phase microextraction-gas chromatography–mass spectrometry
A method for the simultaneous determination of 22 volatile organic compounds (VOCs), methyl- tert-butyl ether (MTBE), 1,4-dioxane, 2-methylisoborneol (2-MIB) and geosmin in water by headspace solid phase microextraction (SPME)-gas chromatography–mass spectrometry (GC–MS) is described. Three types of...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 2005-08, Vol.548 (1), p.79-85 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A method for the simultaneous determination of 22 volatile organic compounds (VOCs), methyl-
tert-butyl ether (MTBE), 1,4-dioxane, 2-methylisoborneol (2-MIB) and geosmin in water by headspace solid phase microextraction (SPME)-gas chromatography–mass spectrometry (GC–MS) is described. Three types of SPME fibers (carboxen (CAR)/polydimethylsiloxane (PDMS), divinylbenzene (DVB)/PDMS and 100-μm PDMS) were evaluated to achieve the method detection limits and linear range required in Japanese water regulation. A 100-μm PDMS was found to be the best coating to obtain a wide range of linearity for the target compounds in multiple-component system. CAR/PDMS and DVB/PDMS of adsorbent type fibers showed a narrow linear range for 22 VOCs, MTBE and 1,4-dioxane at the μg/l levels due to the limited capacity.
The detection limits of this method were 0.01–0.05
μg/l for 22 VOCs, 0.01
μg/l for MTBE, 1.2
μg/l for 1,4-dioxane, 0.6
ng/l for 2-MIB and 0.3
ng/l for geosmin. The recoveries of 22 VOCs and MTBE from a river water sample spiked at 1
μg/l were between 93.7 and 104.0%, with R.S.D. values of between 1.7 and 9.5%. Those of 1,4-dioxane, 2-MIB and geosmin at 5
μg/l, 10
ng/l and 10
ng/l, respectively, were 109.1, 95.9 and 97.4%, with R.S.D. values of 2.0, 5.6 and 1.8%. The method provided linear range from 0.1 to 100
μg/l for 21 VOCs and MTBE, 0.1 to 50
μg/l for
m,
p-xylene, 5 to 100
μg/l for 1-4dioxane and 1 to 100
ng/l for 2-MIB and geosmin. |
---|---|
ISSN: | 0003-2670 1873-4324 |
DOI: | 10.1016/j.aca.2005.05.077 |