REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR DETERMINATION OF 5-FLUOROURACIL IN RABBIT PLASMA

A simple, efficient, accurate and selective HPLC method has been developed and validated successfully for the estimation of 5-fluorouracil in rabbit plasma. The drug was eluted by using Supelco C18 column (1.5 cm x 4.6 mm, 5 μm) with a mobile phase consisting of methanol and water (20: 80, v/v) by a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta Poloniae pharmaceutica 2017-03, Vol.74 (2), p.379-383
Hauptverfasser: Nasir, Bushra, Muhammad Ranjha, Nazar, Hanif, Muhammad, Abbas, Ghulam
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A simple, efficient, accurate and selective HPLC method has been developed and validated successfully for the estimation of 5-fluorouracil in rabbit plasma. The drug was eluted by using Supelco C18 column (1.5 cm x 4.6 mm, 5 μm) with a mobile phase consisting of methanol and water (20: 80, v/v) by adjusting pH at 3.2, using perchloric acid solution. The retention time was found to be 4.107 with a flow rate of I mL/min. Multiple validation parameters evaluated with high accuracy indicating that the current method sufficiently qualifies the recommended criteria. Regression value obtained from linearity curve was R² = 0.999 and percentage recovery obtained was ranged from 96.6 to 102.5%. A fine response in short run time with perfect resolution made the method highly suitable for pharmacokinetic studies.
ISSN:0001-6837