REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY METHOD FOR DETERMINATION OF 5-FLUOROURACIL IN RABBIT PLASMA
A simple, efficient, accurate and selective HPLC method has been developed and validated successfully for the estimation of 5-fluorouracil in rabbit plasma. The drug was eluted by using Supelco C18 column (1.5 cm x 4.6 mm, 5 μm) with a mobile phase consisting of methanol and water (20: 80, v/v) by a...
Gespeichert in:
Veröffentlicht in: | Acta Poloniae pharmaceutica 2017-03, Vol.74 (2), p.379-383 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A simple, efficient, accurate and selective HPLC method has been developed and validated successfully for the estimation of 5-fluorouracil in rabbit plasma. The drug was eluted by using Supelco C18 column (1.5 cm x 4.6 mm, 5 μm) with a mobile phase consisting of methanol and water (20: 80, v/v) by adjusting pH at 3.2, using perchloric acid solution. The retention time was found to be 4.107 with a flow rate of I mL/min. Multiple validation parameters evaluated with high accuracy indicating that the current method sufficiently qualifies the recommended criteria. Regression value obtained from linearity curve was R² = 0.999 and percentage recovery obtained was ranged from 96.6 to 102.5%. A fine response in short run time with perfect resolution made the method highly suitable for pharmacokinetic studies. |
---|---|