Measurement of local gas holdup in bubble columns via a non-isokinetic withdrawal method

An inexpensive method was developed to measure local gas holdup based on withdrawal of the air–liquid dispersion in bioreactors under non-isokinetic conditions. The method was tested with several suction probe designs and withdrawal pressures using coalescing and non-coalescing model media as well a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical engineering science 2005-12, Vol.60 (24), p.6929-6938
Hauptverfasser: García-Salas, Sergio, Orozco-Alvarez, Carlos, Michael Porter, R., Thalasso, Frederic
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An inexpensive method was developed to measure local gas holdup based on withdrawal of the air–liquid dispersion in bioreactors under non-isokinetic conditions. The method was tested with several suction probe designs and withdrawal pressures using coalescing and non-coalescing model media as well as during yeast fermentations. Simultaneously, gas holdup was measured manometrically. With a straight end probe and vacuum pressure of 3 kPa, local gas holdup measurements presented a relative error < 6 % compared to the manometric method, independently of the media composition. This method was used to characterize local gas holdup in a bubble column. Two new parameters are proposed to characterize non-gassed volume and gas holdup homogeneity.
ISSN:0009-2509
1873-4405
DOI:10.1016/j.ces.2005.06.010