Use of the Apollo detachable-tip microcatheter for endovascular embolization of arteriovenous malformations and arteriovenous fistulas

Liquid embolic agents have revolutionized endovascular management of arteriovenous malformations (AVMs) and arteriovenous fistulas (AVFs). Nonetheless, since 2005, the US FDA has received more than 100 reports of microcatheter breakage or entrapment related to Onyx embolization, including 9 deaths....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of neurosurgery 2019-03, Vol.130 (3), p.963-971
Hauptverfasser: Flores, Bruno C, See, Alfred P, Weiner, Gregory M, Jankowitz, Brian T, Ducruet, Andrew F, Albuquerque, Felipe C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Liquid embolic agents have revolutionized endovascular management of arteriovenous malformations (AVMs) and arteriovenous fistulas (AVFs). Nonetheless, since 2005, the US FDA has received more than 100 reports of microcatheter breakage or entrapment related to Onyx embolization, including 9 deaths. In 2014, the Apollo detachable-tip microcatheter became the first of its kind available in the US. Since then, few reports on its safety have been published. The authors conducted a retrospective review of endovascular cases by searching the patient databases at 2 tertiary cerebrovascular centers (Barrow Neurological Institute and University of Pittsburgh Medical Center). Patients who underwent endovascular embolization of an AVM or AVF using the Apollo microcatheter were identified. Patient demographics and lesion characteristics were collected. The authors analyzed Apollo-specific endovascular variables, such as number of microcatheterizations, sessions, and pedicles embolized; microcatheter tip detachment status; obliteration rate; and endovascular- and microcatheter-related morbidity and mortality. From July 2014 to October 2016, a total of 177 embolizations using the Apollo microcatheter were performed in 61 patients (mean age 40.3 years). The most frequent presentation was hemorrhage (22/61, 36.1%). Most lesions were AVMs (51/61, 83.6%; mean diameter 30.6 mm). The mean Spetzler-Martin grade was 2.4. Thirty-nine (76.5%) of 51 patients with AVMs underwent resection. Microcatheterization was successful in 172 pedicles. Most patients (50/61, 82%) underwent a single embolization session. The mean number of pedicles per session was 2.5 (range 1-7). Onyx-18 was used in 103 (59.9%), N-butyl cyanoacrylate (NBCA) in 44 (25.6%), and Onyx-34 in 25 (14.5%) of the 172 embolizations. In 45.9% (28/61) of the patients, lesion obliteration of 75% or greater was achieved. Tip detachment occurred in 19.2% (33/172) of microcatheters. Fifty-three (86.9%) of the 61 patients who underwent embolization with the Apollo microcatheter had good functional outcomes (modified Rankin Scale score 0-2). No unintended microcatheter fractures or related morbidity was observed. One patient died of intraprocedural complications unrelated to microcatheter selection. In the univariate analysis, microcatheter tip detachment (p = 0.12), single embolized pedicles (p = 0.12), and smaller AVM nidus diameter (p = 0.17) correlated positively with high obliteration rates (> 90%). In the multivariate ana
ISSN:0022-3085
1933-0693
1933-0693
DOI:10.3171/2017.9.JNS17397