Dynamic charge acceptance and hydrogen evolution of a new MXene additive in advanced lead-acid batteries via a rapid screening three-electrode method

A methodology to screen additives in lead-acid batteries is critical. We developed a three-electrode system that can rapidly check the dynamic charge acceptance (DCA) and hydrogen evolution of electrodes. The electrode with 2% MXene and 0.2% carbon black shows a better DCA, which indicates its great...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical communications (Cambridge, England) England), 2018-04, Vol.54 (28), p.3456-3459
Hauptverfasser: Kang, Shuai, Shang, Mingwei, Spence, Matthew A, Andrew, Michael, Liu, Shuangyi, Niu, Junjie
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A methodology to screen additives in lead-acid batteries is critical. We developed a three-electrode system that can rapidly check the dynamic charge acceptance (DCA) and hydrogen evolution of electrodes. The electrode with 2% MXene and 0.2% carbon black shows a better DCA, which indicates its great potential in the start-stop technology.