The value of 99mTc-MDP bone SPECT/CT in evaluation of patients with painful knee prosthesis
OBJECTIVEThe purpose of this study was to assess the incremental value of technetium-99m-methyl diphosphonate (Tc-MDP) single-photon emission computed tomography/computed tomography (SPECT/CT) over Tc-MDP two-phase bone scan (TPBS) in the assessment of the patients with pain following knee arthropla...
Gespeichert in:
Veröffentlicht in: | Nuclear medicine communications 2018-05, Vol.39 (5), p.397-404 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | OBJECTIVEThe purpose of this study was to assess the incremental value of technetium-99m-methyl diphosphonate (Tc-MDP) single-photon emission computed tomography/computed tomography (SPECT/CT) over Tc-MDP two-phase bone scan (TPBS) in the assessment of the patients with pain following knee arthroplasty.
PATIENTS AND METHODSTc-MDP TPBS and Tc-MDP SPECT/CT were performed in 49 patients with knee pain after knee arthroplasty. The scans were reviewed by two readers (nuclear medicine physician and musculoskeletal radiologist). Tc-MDP SPECT/CT studies were interpreted in conjunction with TPBS in this retrospective study to identify the pain generator in painful knee prosthesis. The final diagnosis was established based on a combination of histopathological/cytological findings, other imaging findings (e.g. MRI, radiolabelled white scan), clinical decisions, and management outcomes (including subsequent intraoperative findings).
RESULTSIn diagnosing infection or aseptic loosening, a definitive outcome regarding the presence/absence of aseptic loosening or periprosthetic infection was obtained in 41 patients. (a) Sensitivity of Tc-MDP SPECT/CT [100%; 95% confidence interval (CI)66.4–100%] was higher than Tc-MDP TPBS (88.9%; 95% CI51.8–99.7%). (b) Specificity of Tc-MDP SPECT/CT (75%; 95% CI53.3–90.2%) was considerably higher than Tc-MDP TPBS (30%; 95% CI11.9–54.3%). Alternative diagnoses were identified in 21/49 (43%) patients on Tc-MDP SPECT/CT, which could not be ascertained on Tc-MDP TPBS alone.
CONCLUSIONTc-MDP SPECT/CT has better sensitivity and specificity compared with Tc-MDP TPBS in diagnosis of aseptic loosening and periprosthestic infection in patients with painful knee arthroplasty. Tc-MDP SPECT/CT identified alternative causes of pain in 43% of patients, which was not identified by Tc-MDP TPBS. |
---|---|
ISSN: | 0143-3636 1473-5628 |
DOI: | 10.1097/MNM.0000000000000825 |