Sequential high intensity focused ultrasound (HIFU) ablation in the treatment of benign multinodular goitre: an observational retrospective study
Objectives Assessing the efficacy and safety of sequential high-intensity focused ultrasound (HIFU) ablation in a multinodular goitre (MNG) by comparing them with single HIFU ablation. Methods One hundred and four (84.6%) patients underwent single ablation of a single nodule (group I), while 19 (15....
Gespeichert in:
Veröffentlicht in: | European radiology 2018-08, Vol.28 (8), p.3237-3244 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objectives
Assessing the efficacy and safety of sequential high-intensity focused ultrasound (HIFU) ablation in a multinodular goitre (MNG) by comparing them with single HIFU ablation.
Methods
One hundred and four (84.6%) patients underwent single ablation of a single nodule (group I), while 19 (15.4%) underwent sequential ablation of two relatively-dominant nodules in a MNG (group II). Extent of shrinkage per nodule [by volume reduction ratio (VRR)], pain scores (by 0-10 visual analogue scale) during and after ablation, and rate of vocal cord palsy (VCP), skin burn and nausea/vomiting were compared between the two groups.
Results
All 19 (100%) sequential ablations completed successfully. The 3- and 6-month VRR of each nodule were comparable between the two groups (
p
> 0.05) and in group II, the 3- and 6-month VRR between the first and second nodules were comparable (
p
= 0.710 and
p
= 0.548, respectively). Pain score was significantly higher in group II in the morning after ablation (2.29 vs 1.15,
p
= 0.047) and nausea/vomiting occurred significantly more frequently in group II (15.8% vs 0.0%,
p
= 0.012). However, VCP and skin burn were comparable (
p
> 0.05).
Conclusions
Sequential ablation had comparable efficacy and safety as single ablation. However, patients undergoing sequential ablation are at higher likelihood of pain in the following morning and nausea/vomiting after ablation.
Key Points
• Sequential HIFU ablation is well-tolerated in patients with two dominant thyroid nodules
• More pain is experienced in the morning following sequential HIFU ablation
• More nausea/vomiting is experienced following sequential HIFU ablation |
---|---|
ISSN: | 0938-7994 1432-1084 |
DOI: | 10.1007/s00330-018-5333-2 |