Apically Extruded Debris during Root Canal Instrumentation with Reciproc Blue, HyFlex EDM, and XP-endo Shaper Nickel-titanium Files
The purpose of this study was to investigate the amount of apically extruded debris by Reciproc Blue (REC Blue; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent, Altstätten, Switzerland), and XP-endo Shaper (XPS; FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) files during root canal prep...
Gespeichert in:
Veröffentlicht in: | Journal of endodontics 2018-05, Vol.44 (5), p.856-859 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The purpose of this study was to investigate the amount of apically extruded debris by Reciproc Blue (REC Blue; VDW, Munich, Germany), HyFlex EDM (HEDM; Coltene/Whaledent, Altstätten, Switzerland), and XP-endo Shaper (XPS; FKG Dentaire SA, La Chaux-de-Fonds, Switzerland) files during root canal preparation at body temperature.
Sixty extracted single-rooted mandibular premolar human teeth were randomly assigned to 3 groups (n = 20). The canals were instrumented using 1 of the following instruments: REC Blue, HEDM, or XPS. Apically extruded debris during instrumentation was collected into preweighed Eppendorf tubes. All the procedures were performed at 35°C. The amount of extruded debris was calculated by subtracting the weight value of the tooth-free apparatus from the postpreparation weight value. The data were analyzed using the Kruskal-Wallis test at a 5% significance level.
All the instruments tested caused extrusion of some debris from the apical foramen. XPS extruded significantly less debris from the apex than REC Blue (P .05).
Within the limitations of this in vitro study, the amount of apically extruded debris registered for the different files tested was REC Blue > HEDM > XPS, with a statistical difference only between XPS and REC Blue.
•We compared the amounts of debris extruded from the apex during root canal treatment with Reciproc Blue, HyFlex EDM, and XP-endo Shaper files.•All the instruments tested caused extrusion of some debris from the apical foramen.•XP-endo Shaper files extruded significantly less debris from the apex than Reciproc Blue files (P .05). |
---|---|
ISSN: | 0099-2399 1878-3554 |
DOI: | 10.1016/j.joen.2018.01.018 |