Stimulated Raman spectroscopy of analytes evanescently probed by a silicon nitride photonic integrated waveguide
We report, to the best of our knowledge, the first demonstration of stimulated Raman spectroscopy enhanced by a nanophotonic integrated circuit. The Raman response of low-concentration dimethyl sulfoxide is evanescently probed via centimeter-long wire waveguides. A signal enhancement of close to fiv...
Gespeichert in:
Veröffentlicht in: | Optics letters 2018-03, Vol.43 (6), p.1403-1406 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report, to the best of our knowledge, the first demonstration of stimulated Raman spectroscopy enhanced by a nanophotonic integrated circuit. The Raman response of low-concentration dimethyl sulfoxide is evanescently probed via centimeter-long wire waveguides. A signal enhancement of close to five orders of magnitude, as compared to the case of on-chip spontaneous Raman scattering, is demonstrated. This significant enhancement factor allows for the use of continuous-wave lasers with milliwatt-level power and uncooled detectors and, therefore, sets the basis of future all-on-a-chip Raman spectrometers suitable for both gas and liquid detection. |
---|---|
ISSN: | 0146-9592 1539-4794 |
DOI: | 10.1364/OL.43.001403 |