A single liquid chromatography–quadrupole time‐of‐flight mass spectrometric method for the quantification of total antibody, antibody‐conjugated drug and free payload of antibody–drug conjugates

A single hybrid affinity‐captured‐LC‐TOF‐MS/MS method was developed and applied for the quantification of total antibody, antibody conjugated drug and free payload of antibody drug conjugate (ADC). Adcetris®, a valine–citrulline monomethyl auristatin E conjugated ADC, was used as a model ADC compoun...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Biomedical chromatography 2018-07, Vol.32 (7), p.e4229-n/a
Hauptverfasser: Byeon, Jin‐Ju, Park, Min‐Ho, Shin, Seok‐Ho, Lee, Byeong ill, Park, Yuri, Choi, Jangmi, Kim, Nahye, Kang, Yeonjae, Shin, Young G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A single hybrid affinity‐captured‐LC‐TOF‐MS/MS method was developed and applied for the quantification of total antibody, antibody conjugated drug and free payload of antibody drug conjugate (ADC). Adcetris®, a valine–citrulline monomethyl auristatin E conjugated ADC, was used as a model ADC compound. A quadratic regression (weighted 1/concentration) was used to fit calibration curves over the concentration range 30.65–613.00 ng/mL with an equation y = ax2 + bx + c for the antibody‐conjugated drug of Adcetris®. The qualification run met the acceptance criteria of ±25% accuracy and precision values for quality control samples. For the analysis of total antibody, a signature peptide (TTPPVLDSDGSFFLYSK, molecular weight 1874) was used after affinity capture using magnetic beads and on‐bead trypsin digestion. A quadratic regression (weighted 1/concentration) was used to fit calibration curves over the concentration range 5.00–100.00 μg/mL with an equation y = ax2 + bx + c for total antibody. For free payload analysis of monomethyl auristatin E, a protein precipitation method followed by LC‐TOF‐MS/MS analysis was used. A quadratic regression (weighted 1/concentration) was used to fit calibration curves over the concentration range 1.01–2200 ng/mL with an equation y = ax2 + bx + c for free payload. Pharmacokinetic study samples and in vitro stability samples in rat were successfully analyzed by this a hybrid affinity‐captured‐LC‐TOF‐MS/MS method. This single platform method is a useful complementary method for the pharmacokinetics study of ADC with valine–citrulline linker at the early drug discovery stage.
ISSN:0269-3879
1099-0801
DOI:10.1002/bmc.4229