Effects of Fasting on 18F-DCFPyL Uptake in Prostate Cancer Lesions and Tissues with Known High Physiologic Uptake
In the literature, a 4- to 6-h fast is recommended before a patient undergoes PET/CT with 2-(3-(1-carboxy-5-[(6-18F-fluoro-pyridine-3-carbonyl)-amino]-pentyl)-ureido)-pentanedioic acid (18F-DCFPyL); however, a scientific underpinning for this recommendation is lacking. Therefore, we performed a stud...
Gespeichert in:
Veröffentlicht in: | The Journal of nuclear medicine (1978) 2018-07, Vol.59 (7), p.1081-1084 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In the literature, a 4- to 6-h fast is recommended before a patient undergoes PET/CT with 2-(3-(1-carboxy-5-[(6-18F-fluoro-pyridine-3-carbonyl)-amino]-pentyl)-ureido)-pentanedioic acid (18F-DCFPyL); however, a scientific underpinning for this recommendation is lacking. Therefore, we performed a study to determine the impact of fasting on 18F-DCFPyL uptake. Methods: The study included 50 patients who fasted at least 6 h before 18F-DCFPyL administration and 50 patients who did not. Activity (SUVmax) was measured in lesions characteristic of prostate cancer and in normal tissues known to express high physiologic uptake. Results: Uptake in suspected lesions did not differ between the cohorts. 18F-DCFPyL uptake in the submandibular gland, liver, and spleen was significantly higher in the fasting than the nonfasting cohort. Conclusion: Our data show that fasting does not significantly affect 18F-DCFPyL uptake in suspected malignant lesions but does result in significantly lower 18F-DCFPyL uptake in tissues with high physiologic uptake. The absolute differences in uptake were relatively small; therefore, the effects of fasting on the diagnostic performance can be considered negligible. |
---|---|
ISSN: | 1535-5667 |
DOI: | 10.2967/jnumed.117.207316 |