Endovascular Stent-Graft Repair of Spontaneous Isolated Dissection of the Superior Mesenteric Artery

Purpose The aim of this study was to determine the short-term clinical outcomes, safety, and efficacy of covered stents implantation for patients with spontaneous isolated dissection of the superior mesenteric artery (SMA). Materials and Methods Between October 2013 and December 2016, 12 patients (m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiovascular and interventional radiology 2018-05, Vol.41 (5), p.692-698
Hauptverfasser: Wen, Didi, Wang, Zhankui, Yu, Jing, Zhang, Wenlong, Yang, Xiaobin, He, Hua, Zhang, Xuexin, Lin, Ying, An, Rui, Zheng, Minwen, Xu, Jian
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose The aim of this study was to determine the short-term clinical outcomes, safety, and efficacy of covered stents implantation for patients with spontaneous isolated dissection of the superior mesenteric artery (SMA). Materials and Methods Between October 2013 and December 2016, 12 patients (mean age, 50.0 ± 6.2 years; range 38–62 years) with spontaneous isolated dissection of SMA received endovascular treatment with the placement of covered stents at our institution. Patients’ clinical characteristics were analyzed including sex, age, medical history, risk factors, symptoms, and diagnostic imaging modality. The technical and clinical successes of covered stents placement were retrospectively analyzed. Standard follow-up protocol included abdominal computed tomography angiography and clinical examinations at 1, 3, 6, and 12 months and annually thereafter to confirm patients’ general condition. Results All dissections were located at the anterior wall and around the convex curvature of SMA. The mean length of the SMA dissection was 37.8 ± 31.5 mm (range 6.9–105.0 cm). Immediate technical success was defined as normal blood flow in the SMA and no contrast medium in the false lumen achieved in all patients. The mean duration of follow-up was 26.9 ± 7.2 months (range 16–36 months). Abdominal CT angiography demonstrated that no patients experienced endoleak or stent stenosis during follow-up. Conclusions For symptomatic spontaneous isolated dissection of SMA in patients without aneurysms rupture and bowel necrosis, endovascular treatment with covered stents may be a safe and effective treatment option with a good short-term outcome.
ISSN:0174-1551
1432-086X
DOI:10.1007/s00270-018-1889-0