Replacement of a Stenotic Quadricuspid Aortic Valve With a Sutureless Prosthesis
Quadricuspid aortic valve is a rare occurrence, usually presenting with insufficiency rather than stenosis. We report an aortic valve replacement in a septuagenarian with a stenotic quadricuspid aortic valve, achieving a good result with a Perceval (Sorin Biomedica Cardio Srl, Sallugia, Italy) sutur...
Gespeichert in:
Veröffentlicht in: | The Annals of thoracic surgery 2018-06, Vol.105 (6), p.e249-e250 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Quadricuspid aortic valve is a rare occurrence, usually presenting with insufficiency rather than stenosis. We report an aortic valve replacement in a septuagenarian with a stenotic quadricuspid aortic valve, achieving a good result with a Perceval (Sorin Biomedica Cardio Srl, Sallugia, Italy) sutureless bioprosthesis. We emphasize the particular technique of implantation and possible pitfalls. Sutureless bioprosthetic valves present a feasible option for aortic valve replacement in patients with uncommon valve morphologies, aiming to reduce operative time. |
---|---|
ISSN: | 0003-4975 1552-6259 |