Significance of hyperechoic marks observed during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules
Objective To examine the association between the appearance of hyperechoic marks (HEMs) during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules and nodule shrinkage at 6 months. Methods One hundred and thirty-six patients who underwent HIFU for benign thyroid nodule were a...
Gespeichert in:
Veröffentlicht in: | European radiology 2018-06, Vol.28 (6), p.2675-2681 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective
To examine the association between the appearance of hyperechoic marks (HEMs) during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules and nodule shrinkage at 6 months.
Methods
One hundred and thirty-six patients who underwent HIFU for benign thyroid nodule were analysed. An independent person carefully examined the B-mode ultrasonography screen for the appearance of HEMs after each pulse. The proportion of HEMs (%) was calculated by: [(Number of pulses that resulted in HEMs) / (Total number of pulses given per treatment) × 100] while the nodule shrinkage was measured by volume reduction ratio (VRR) = [Baseline volume–volume at 6 months]/[Baseline volume] * 100. Treatment success was defined as VRR ≥ 50 %.
Results
Patients with HEMs (n=91) had significantly greater 6-month VRR than those without HEMs (n=45) (65.76 % vs. 36.76 %, p |
---|---|
ISSN: | 0938-7994 1432-1084 |