Assessment of the Embryonic Stem Cell Test and application and use in the pharmaceutical industry

BACKGROUND: The European Centre for the Validation of Alternative Methods (ECVAM) designed the Embryonic Stem Cell Test (EST) as a tool for classifying developmentally toxic compounds. An in vitro tool to assess developmental toxicity would be of great value to the pharmaceutical industry to help wi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Birth defects research. Part B. Developmental and reproductive toxicology 2008-04, Vol.83 (2), p.104-111
Hauptverfasser: Paquette, Jennifer A., Kumpf, Steven W., Streck, Randal D., Thomson, Jason J., Chapin, Robert E., Stedman, Donald B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:BACKGROUND: The European Centre for the Validation of Alternative Methods (ECVAM) designed the Embryonic Stem Cell Test (EST) as a tool for classifying developmentally toxic compounds. An in vitro tool to assess developmental toxicity would be of great value to the pharmaceutical industry to help with toxicity‐associated attrition. METHODS: ECVAM's EST protocol was used, but employing a different mouse embryonic stem cell (ESC) line and an alternative differentiation medium. A subset of the compounds used to validate the EST assay along with a number of in‐house pharmaceutical compounds plus marketed pharmaceutical compounds were used to assess the EST performance with receptor‐mediated compounds. RESULTS: Our results with ECVAM compounds mirrored ECVAM's. Compounds that were developmentally toxic in vivo were classified by the EST as moderate risk. Overall, the accuracy was 75% with the current set of data and the predictivity of low‐, moderate‐, and high‐risk compounds was 90, 71, and 60% while the precision was 59, 86, and 100%, respectively. Interestingly, a number of the non‐developmentally toxic compounds had values for the 3T3 IC50 values, which were lower than the ESC IC50 and ID50, a situation not taken into account by ECVAM when designing the EST algorithm. CONCLUSIONS: The assay as currently constructed has a significant false‐positive rate (∼40%), but a very low false‐negative rate (∼7%). Additional moderate‐ and high‐risk compounds need to be assessed to increase confidence, accuracy, and understanding in the EST's predictivity. Birth Defects Res (Part B), 2008. © 2008 Wiley‐Liss, Inc.
ISSN:1542-9733
1542-9741