Oesophageal or transgastric views for estimating mean pulmonary artery pressure with transoesophageal echocardiography: A prospective observational study
BACKGROUNDRecent data suggest that in cardiac surgical patients, the pulmonary artery acceleration time (PAT) is useful for estimating mean pulmonary artery pressure (MPAP) noninvasively with transoesophageal echocardiography (TOE). The pulmonary valve can be visualised from multiple echocardiograph...
Gespeichert in:
Veröffentlicht in: | European journal of anaesthesiology 2018-05, Vol.35 (5), p.349-355 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | BACKGROUNDRecent data suggest that in cardiac surgical patients, the pulmonary artery acceleration time (PAT) is useful for estimating mean pulmonary artery pressure (MPAP) noninvasively with transoesophageal echocardiography (TOE). The pulmonary valve can be visualised from multiple echocardiographic windows, but it is unclear which, if any, view correlates best with MPAP.
OBJECTIVE(S)To compare the PAT measured with TOE from oesophageal and transgastric views with MPAP obtained invasively with a pulmonary artery catheter.
DESIGNA prospective observational study.
SETTINGSt. Vincentʼs Hospital, Melbourne, a university tertiary referral centre in Australia.
PATIENTSSixty-three patients having cardiac surgery were included in our study. All patients had insertion of both a TOE probe and pulmonary artery catheter; this is the routine standard of care in our centre.
INTERVENTION(S)Nil.
MAIN OUTCOME MEASURESDuring a period of haemodynamic stability, the PAT was measured first from an oesophageal view and then immediately after from a transgastric view. The results were then compared with the invasively measured MPAP.
RESULTSSimultaneous measurements of MPAP and PAT were taken in 63 patients. In two patients, these measurements were not possible in the transgastric position due to an inability to visualise the right ventricular outflow tract and pulmonary valve. A Bland–Altman analysis of the PAT measured from the upper oesophageal and transgastric views showed a mean difference of 1 ms and limits of agreement of −18 to 16 ms. The area under the receiver operating curves for predicting pulmonary hypertension with PAT were upper oesophageal view 0.99 [95% confidence interval (CI), 0.98 to 1.00] and transgastric view 0.99 (95% CI, 0.97 to 1.00). The agreement between the results from these two views in the diagnosis of pulmonary hypertension (defined as PAT 25 mmHg) with a sensitivity of 94.7% and specificity of 97.6%. The transgastric view predicted pulmonary hypertension with a sensitivity of 89.4% and specificity of 95.2%.
CONCLUSIONOesophageal and transgastric measurements of PAT have close agreement and a similar high ability to discriminate between people with and without pulmonary hypertension. The transgastric measurement |
---|---|
ISSN: | 0265-0215 1365-2346 |
DOI: | 10.1097/EJA.0000000000000750 |