Indoor thermal environment, air exchange rates, and carbon dioxide concentrations before and after energy retro fits in Finnish and Lithuanian multi-family buildings

•In Finnish buildings: overheating was common both before and after retrofits and ventilation rates increased after retrofits.•In Lithuanian buildings: indoor temperatures improved after retrofits and ventilation rates decreased while RH increased after retrofits.•Assessing thermal conditions and ve...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Science of the total environment 2018-04, Vol.621, p.398-406
Hauptverfasser: Leivo, Virpi, Prasauskas, Tadas, Du, Liuliu, Turunen, Mari, Kiviste, Mihkel, Aaltonen, Anu, Martuzevicius, Dainius, Haverinen-Shaughnessy, Ulla
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•In Finnish buildings: overheating was common both before and after retrofits and ventilation rates increased after retrofits.•In Lithuanian buildings: indoor temperatures improved after retrofits and ventilation rates decreased while RH increased after retrofits.•Assessing thermal conditions and ventilation crucial for optimal IEQ and energy use. [Display omitted] Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO2) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use.
ISSN:0048-9697
1879-1026
DOI:10.1016/j.scitotenv.2017.11.227