Augmented Quadruple-Phase Contrast Media Administration and Triphasic Scan Protocol Increases Image Quality at Reduced Radiation Dose During Computed Tomography Urography
The aim of this article was to investigate the opacification of the renal vasculature and the urogenital system during computed tomography urography by using a quadruple-phase contrast media in a triphasic scan protocol. A total of 200 patients with possible urinary tract abnormalities were equally...
Gespeichert in:
Veröffentlicht in: | Journal of computer assisted tomography 2018-03, Vol.42 (2), p.216-221 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this article was to investigate the opacification of the renal vasculature and the urogenital system during computed tomography urography by using a quadruple-phase contrast media in a triphasic scan protocol.
A total of 200 patients with possible urinary tract abnormalities were equally divided between 2 protocols. Protocol A used the conventional single bolus and quadruple-phase scan protocol (pre, arterial, venous, and delayed), retrospectively. Protocol B included a quadruple-phase contrast media injection with a triphasic scan protocol (pre, arterial and combined venous, and delayed), prospectively. Each protocol used 100 mL contrast and saline at a flow rate of 4.5 mL. Attenuation profiles and contrast-to-noise ratio of the renal arteries, veins, and urogenital tract were measured. Effective radiation dose calculation, data analysis by independent sample t test, receiver operating characteristic, and visual grading characteristic analyses were performed.
In arterial circulation, only the inferior interlobular arteries in both protocols showed a statistical significance (P < 0.05). Venously, the inferior vena cava, proximal and distal renal veins demonstrated a significant opacification reduction in protocol B than in protocol A (P < 0.001). Protocol B showed a significantly higher mean contrast-to-noise ratio than protocol A (protocol B: 22.68 ± 13.72; protocol A: 14.75 ± 5.76; P < 0.001). Radiation dose was significantly reduced in protocol B (7.38 ± 2.22 mSv) than in protocol A (12.28 ± 2.72 mSv) (P < 0.001). Visual grading characteristic (P < 0.027) and receiver operating characteristic (P < 0.0001) analyses demonstrated a significant preference for protocol B.
In computed tomography urography, augmented quadruple-phase contrast media and triphasic scan protocol usage increases the image quality at a reduced radiation dose. |
---|---|
ISSN: | 0363-8715 1532-3145 |
DOI: | 10.1097/RCT.0000000000000674 |