Portable CT Pulmonary Angiogram in an Infant on Veno-Arterial Extracorporeal Membrane Oxygenation in the Pediatric Intensive Care Unit
Computed tomography (CT) has been shown to change management in children on extracorporeal membrane oxygenation (ECMO). Although techniques have been described to transport these critically ill patients to the CT suite in the radiology department, transport out of the intensive care setting is not w...
Gespeichert in:
Veröffentlicht in: | Current problems in diagnostic radiology 2019-03, Vol.48 (2), p.189-192 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Computed tomography (CT) has been shown to change management in children on extracorporeal membrane oxygenation (ECMO). Although techniques have been described to transport these critically ill patients to the CT suite in the radiology department, transport out of the intensive care setting is not without risk, and using portable CT is a practical alternative. However, obtaining a CT pulmonary angiogram (CTPA) in a patient on veno-arterial (VA) ECMO presents unique challenges due to bypass of the cardiopulmonary system, which may lead to suboptimal opacification of the pulmonary arteries.
We describe a method to obtain a diagnostic CTPA study in an infant on VA ECMO in the intensive care unit using portable CT. Our solution involved temporary withholding ECMO and using the venous cannula to deliver a compact contrast bolus to the right atrium to adequately opacify the pulmonary arteries. Special attention was given to the delivery of the contrast bolus, which was given by hand injection, to ensure it coincided with image acquisition and minimized the time ECMO was withheld.
We were able to successfully obtain a diagnostic CTPA study in an infant on VA ECMO in the intensive care unit using portable CT. Conclusion: This case demonstrates that in select instances CTPA in infants on VA ECMO can be achieved using a portable CT system. |
---|---|
ISSN: | 0363-0188 1535-6302 |
DOI: | 10.1067/j.cpradiol.2017.10.005 |