B1 artifact reduction in abdominal DCE‐MRI using kT‐points: First clinical assessment of dynamic RF shimming at 3T

Background The excitation inhomogeneity artifact occurring at 3T in the abdomen can lead to dramatic loss of signal and contrast, thereby hampering diagnosis. Purpose To assess excitation homogeneity and image quality achieved by nonselective prototypical kT‐points pulses, compared to tailored stati...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetic resonance imaging 2018-06, Vol.47 (6), p.1562-1571
Hauptverfasser: Tomi‐Tricot, Raphaël, Gras, Vincent, Mauconduit, Franck, Legou, François, Boulant, Nicolas, Gebhardt, Matthias, Ritter, Dieter, Kiefer, Berthold, Zerbib, Pierre, Rahmouni, Alain, Vignaud, Alexandre, Luciani, Alain, Amadon, Alexis
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background The excitation inhomogeneity artifact occurring at 3T in the abdomen can lead to dramatic loss of signal and contrast, thereby hampering diagnosis. Purpose To assess excitation homogeneity and image quality achieved by nonselective prototypical kT‐points pulses, compared to tailored static RF shimming, in clinical routine on a commercial dual‐transmit scanner. Study Type Retrospective study with Institutional Review Board approval; informed consent was waived. Population Fifty consecutive patients referred for liver MRI at a single hospital. Field Strength/Sequence 3D breath‐hold dynamic contrast‐enhanced (DCE) MRI at 3T. Assessment Flip angle homogeneity was estimated via numerical simulation based on measured static and RF field maps. In all, 20 of the 50 patients underwent DCE‐MRI while a pulse designer was present. The effect of RF shimming and kT‐point pulses could be compared by repeating the acquisition with each transmit scheme before injection and in the late phase. Signal homogeneity, T1 contrast, enhancement quality, structure details, and global image quality were assessed on a 4‐level scale (0 to 3) by two radiologists. Statistical tests Means were compared using Wilcoxon signed‐rank tests. Results Normalized root mean square flip angle error was significantly reduced with kT‐points compared to static RF shimming (8.5% ± 1.5% [mean ± standard deviation, SD] vs. 20.4% ± 9.8%; P < 0.0001). The worst case (heavy ascites) led to 13.0% (kT‐points) vs. 54.9% (RF shimming). Global image quality was significantly higher for kT‐points (2.3 ± 0.5 vs. 1.9 ± 0.6; P = 0.008). One subject's examination was judged unusable with RF shimming by one reader, none with kT‐points. 85% of kT‐points acquisitions were graded at least 2/3, and only 55% for static RF shimming. Data Conclusion KT‐points reduce excitation inhomogeneity quantitatively and qualitatively, especially in patients with ascites and prone to B1 shading. Level of Evidence: 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1562–1571.
ISSN:1053-1807
1522-2586
DOI:10.1002/jmri.25908