Highly sensitive determination of alendronate in human plasma and dialysate using metal-free HPLC-MS/MS

•A metal-free HPLC-MS/MS method was developed for analysis of alendronate.•A L-column2 ODS metal-free column was requires in the assay.•The present study provided the high sensitivity with lower LLOQs.•This method can be applied to clinical and toxicological analyses. A highly sensitive method was d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Legal medicine (Tokyo, Japan) Japan), 2018-01, Vol.30, p.14-20
Hauptverfasser: Yamada, Miho, Lee, Xiao-Pen, Fujishiro, Masaya, Iseri, Ken, Watanabe, Makoto, Sakamaki, Hiroshi, Uchida, Naoki, Matsuyama, Takaaki, Kumazawa, Takeshi, Takahashi, Haruo, Ishii, Akira, Sato, Keizo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•A metal-free HPLC-MS/MS method was developed for analysis of alendronate.•A L-column2 ODS metal-free column was requires in the assay.•The present study provided the high sensitivity with lower LLOQs.•This method can be applied to clinical and toxicological analyses. A highly sensitive method was developed for the analysis of alendronate in human plasma and dialysate using MonoSpin™ SAX® extraction and metal-free high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) following methylation with trimethylsilyldiazomethane. The chromatographic separation of the derivatives for alendronate and alendronate-d6 was achieved on an L-column2 ODS metal-free column (50 mm  ×  2 mm i.d., particle size 3 µm) with a linear gradient elution system composed of 10 mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.3 ml/min. Quantification was performed by multiple reaction monitoring (MRM) with positive-ion electrospray ionization (ESI). Distinct peaks were observed for alendronate and for the internal standard on each channel within 1 min. The regression equations showed good linearity within the ranges of 2.0–100 ng/0.5 ml for the plasma and 1.0–100 ng/0.5 ml for the dialysate, with the limits of detection at 1.0 ng/0.5 ml for the plasma and 0.5 ng/0.5 ml for the dialysate. Extraction efficiencies for alendronate for the plasma and dialysate were 41.1–51.2% and 63.6–73.4%, respectively. The coefficient of variation (CV) was ≤8.5%. The method was successfully applied to the analyses of real plasma and dialysate samples derived after intravenous administration of alendronate.
ISSN:1344-6223
1873-4162
DOI:10.1016/j.legalmed.2017.11.003