Reproducibility of CMRO2 determination using dynamic 17 O MRI

PURPOSETo assess the reproducibility of 17 O MRI-based determination of the cerebral metabolic rate of oxygen consumption (CMRO2 ) in healthy volunteers. To assess the influence of image acquisition and reconstruction parameters on dynamic quantification of functional parameters such as CMRO2 .METHO...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Magnetic resonance in medicine 2018-06, Vol.79 (6), p.2923-2934
Hauptverfasser: Niesporek, Sebastian C, Umathum, Reiner, Lommen, Jonathan M, Behl, Nicolas G R, Paech, Daniel, Bachert, Peter, Ladd, Mark E, Nagel, Armin M
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PURPOSETo assess the reproducibility of 17 O MRI-based determination of the cerebral metabolic rate of oxygen consumption (CMRO2 ) in healthy volunteers. To assess the influence of image acquisition and reconstruction parameters on dynamic quantification of functional parameters such as CMRO2 .METHODSDynamic 17 O MRI data were simulated and used to investigate influences of temporal resolution (Δt) and partial volume correction (PVC) on the determination of CMRO2 . Three healthy volunteers were examined in two separate examinations. In vivo 17 O MRI measurements were conducted with a nominal spatial resolution of (7.5 mm)3 using a density-adapted radial sequence with golden angle acquisition scheme. In each measurement, 4.0 ± 0.1 L of 70%-enriched 17 O gas were administered using a rebreathing system. Data were corrected with a PVC algorithm, and CMRO2 was determined in gray matter (GM) and white matter (WM) compartments using a three-phase metabolic model (baseline, 17 O inhalation, decay phase).RESULTSComparison with the ground truth of simulations revealed improved CMRO2 determination after application of PVC and with Δt ≤ 2:00 min. Evaluation of in vivo data yields to CMRO2,GM  = 2.31 ± 0.1 μmol/g/min and to CMRO2,WM  = 0.69 ± 0.04 μmol/g/min with coefficients of variation (CoV) of 0.3-5.5% and 4.3-5.0% for intra-volunteer and inter-volunteer data, respectively.CONCLUSIONThis in vivo 17 O inhalation study demonstrated that the proposed experimental setup enables reproducible determination of CMRO2 in healthy volunteers. Magn Reson Med 79:2923-2934, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
ISSN:1522-2594
DOI:10.1002/mrm.26952