Assessment of Bagging Operators Exposure to with PVC Airborne Particulates
Dust consists of tiny solid particles carried by air currents. These particles are formed by many differentprocesses. One of these processes is polymerization of inert plastic such as Polyvinyl Chloride productionplant. According to the Occupational Health and Safety Assessment Series requirements,...
Gespeichert in:
Veröffentlicht in: | Iranian journal of environmental health science & engineering 2008-01, Vol.5 (3), p.187-194 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Dust consists of tiny solid particles carried by air currents. These
particles are formed by many differentprocesses. One of these processes
is polymerization of inert plastic such as Polyvinyl Chloride
productionplant. According to the Occupational Health and Safety
Assessment Series requirements, section 4.4.6,occupational health and
safety risks must be defined and controlled where needed. This field
study wasconducted to evaluate the occupational exposure of packaging
operators to airborne polyvinyl chloridedust in order to health risk
assessment and recommend feasible controlling methods. The
massconcentration of polyvinyl chloride particulate was measured in two
fractions according to the particlesize that expressed as total and
respirable particulates. The Air Sampling Methods, Methods for
theDetermination of Hazardous Substances 14/3, of Health and Safety
Executive were used as a standardsampling protocol. The average mass
concentrations for respirable and total particulates were
measured3.54±0.3 mg/m3 and 11.89±0.8 mg/m3 respectively. Also
health risks of studied condition were estimatedas significant level,
category one, therefore the risk must be reduced below the standard
level. Accordingto the work requirements to reduce the emission rate
and mitigate the health risk exposure, a local exhaustventilation
system design was recommended for bag-filters of hopper tank. |
---|---|
ISSN: | 1735-1979 |