A Prospective Study of 7-Year Experience Using Percutaneous 14-French Pigtail Catheters for Traumatic Hemothorax/Hemopneumothorax at a Level-1 Trauma Center: Size Still Does Not Matter
Background The effectiveness of 14-French (14F) pigtail catheters (PCs) compared to 32-40F chest tubes (CTs) in patients with traumatic hemothorax (HTX) and hemopneumothorax (HPTX) is becoming more well known but still lacking. The aim of our study was to analyze our cumulative experience and outcom...
Gespeichert in:
Veröffentlicht in: | World journal of surgery 2018, Vol.42 (1), p.107-113 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
The effectiveness of 14-French (14F) pigtail catheters (PCs) compared to 32-40F chest tubes (CTs) in patients with traumatic hemothorax (HTX) and hemopneumothorax (HPTX) is becoming more well known but still lacking. The aim of our study was to analyze our cumulative experience and outcomes with PCs in patients with traumatic HTX/HPTX. We hypothesized that PCs would be as effective as CTs.
Methods
Using our PC database, we analyzed all trauma patients who required chest drainage for HTX/HPTX from 2008 to 2014. Primary outcomes of interest, comparing PCs to CTs, included initial drainage output in milliliters (mL), tube insertion-related complications, and failure rate. For our statistical analysis, we used the unpaired Student’s
t
test, Chi-square test, and Wilcoxon rank-sum test. We defined statistical significance as
P
|
---|---|
ISSN: | 0364-2313 1432-2323 |
DOI: | 10.1007/s00268-017-4168-3 |