Adjustment of target weight based on absolute blood volume reduces the frequency of intradialytic morbid events
Introduction: Adequate volume management removing excess volume and at the same time avoiding intradialytic morbid events (IME) remains a core problem in current hemodialysis (HD) therapy. Recently, we developed a feasible method to determine absolute blood volume (Vs, in mL/kg) in patients on HD. T...
Gespeichert in:
Veröffentlicht in: | Hemodialysis international 2018-04, Vol.22 (2), p.254-260 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Introduction: Adequate volume management removing excess volume and at the same time avoiding intradialytic morbid events (IME) remains a core problem in current hemodialysis (HD) therapy. Recently, we developed a feasible method to determine absolute blood volume (Vs, in mL/kg) in patients on HD. The aim of this study was to investigate the suitability of Vs measurements for volume management.
Methods: Following a 4 week baseline phase to quantify the frequency of IME, volume status was determined in a single specified HD session during which Vs was measured using dialysate dilution, volume overload (Vo, L) was measured using bioimpedance spectroscopy, and the occurrence of IME was recorded. Target weight was then adjusted and the frequency of IME was recorded during 4 weeks of follow‐up.
Findings: Forty‐five patients participated in this study. Twenty‐two (49%) patients experienced 66 IME in 12% of HD treatments during baseline. In 15 (33%) patients who experienced IME during volume assessment both Vs (60.7 ± 4.0 vs. 73.7 ± 11.3 mL/kg, P |
---|---|
ISSN: | 1492-7535 1542-4758 |
DOI: | 10.1111/hdi.12582 |