Severe obstructive sleep apnea treatment with oral appliance: the impact on obstructive, central and mixed events

Purpose The aim of this study is to evaluate the effectiveness of two types of oral appliance (OA) in the treatment of severe obstructive sleep apnea syndrome (OSAS) and their impact on the reduction of obstructive, central and mixed apneas. Methods Forty-eight patients suffering from severe OSAS wi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sleep & breathing 2018-03, Vol.22 (1), p.91-98
Hauptverfasser: de Lourdes Rabelo Guimarães, Maria, Hermont, Ana Paula, de Azevedo, Pedro Guimarães, Bastos, Poliana Lima, de Oliveira, Millena Teles Portela, de Melo, Iracema Matos, Ottoboni, Guilherme Salles, Vedolin, Gabriela, Caram, Jorge Machado
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose The aim of this study is to evaluate the effectiveness of two types of oral appliance (OA) in the treatment of severe obstructive sleep apnea syndrome (OSAS) and their impact on the reduction of obstructive, central and mixed apneas. Methods Forty-eight patients suffering from severe OSAS with a history of non-adherence to positive airway pressure therapy were treated with OA (lingual orthosis and combined orthosis). Polysomnography exams were performed before and after treatment. Computed tomography and cephalometric radiography were requested for all patients to evaluate the titrated position of the OA and the airspace obtained. Statistical tests used the Minitab, version 17, program. The level of statistical significance was 5%. Results Before treatment, the mean AHI was 56.3 ± 19.1 events/h. It decreased to 8.1 ± 5.2 after the OA titration ( p  ≤ 0.001). There was a significant reduction in obstructive events from 43.0 ± 20.2 to 7.1 ± 4.6 events/h ( p  ≤ 0.001). The reduction in central events after OA treatment was also significant (from 5.1 ± 9.3 to 0.8 ± 1.9 events/h; p  ≤ 0.001), whereas that in mixed events decreased from 6.4 ± 9.5 to 0.1 ± 0.3 events/h ( p  ≤ 0.001). The minimum oxygen saturation also showed significant improvement after treatment ( p  ≤ 0.001). There was no statistically significant difference between both OA with respect to central events ( p  = 0.22) or mixed events ( p  = 0.98). Conclusion The treatment was effective in reducing obstructive events which were evaluated through the AHI and minimum oxygen saturation. The oral appliances also normalized central and mixed events among patients with severe OSAS.
ISSN:1520-9512
1522-1709
DOI:10.1007/s11325-017-1535-0