Bilirubin coating attenuates the inflammatory response to everolimus-coated stents
The aim of this study was to evaluate the effects of bilirubin- and/or everolimus (EVL)-coated stents to prevent arterial neointimal hyperplasia and inflammation in vitro and in vivo. The stents were prepared by spray coating bare metal stents (BMS) with bilirubin and/or EVL. Study groups were divid...
Gespeichert in:
Veröffentlicht in: | Journal of biomedical materials research. Part B, Applied biomaterials Applied biomaterials, 2018-05, Vol.106 (4), p.1486-1495 |
---|---|
Hauptverfasser: | , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study was to evaluate the effects of bilirubin- and/or everolimus (EVL)-coated stents to prevent arterial neointimal hyperplasia and inflammation in vitro and in vivo. The stents were prepared by spray coating bare metal stents (BMS) with bilirubin and/or EVL. Study groups were divided into (1) BMS, (2) bilirubin-coated stents (BES), (3) commercialized stents (Synergy™; EES), and (4) bilirubin/EVL-coated stents (B-EES). The coating thickness and drug release rates were comparable to previous reports (i.e., |
---|---|