Quantitative measurement of a candidate serum biomarker peptide derived from α2-HS-glycoprotein, and a preliminary trial of multidimensional peptide analysis in females with pregnancy-induced hypertension
Purpose We previously attempted to develop quantitative enzyme-linked immunosorbent assay (ELISA) systems for the PDA039/044/071 peptides, potential serum disease biomarkers (DBMs) of pregnancy-induced hypertension (PIH), primarily identified by a peptidomic approach (BLOTCHIP®-mass spectrometry (MS...
Gespeichert in:
Veröffentlicht in: | Annals of clinical biochemistry 2018-03, Vol.55 (2), p.287-295 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
We previously attempted to develop quantitative enzyme-linked immunosorbent assay
(ELISA) systems for the PDA039/044/071 peptides, potential serum disease biomarkers
(DBMs) of pregnancy-induced hypertension (PIH), primarily identified by a peptidomic
approach (BLOTCHIP®-mass spectrometry (MS)). However, our methodology did not extend to
PDA071 (cysteinyl α2-HS-glycoprotein341–367), due to difficulty to produce a
specific antibody against the peptide. The aim of the present study was to establish an
alternative PDA071 quantitation system using liquid chromatography-multiple reaction
monitoring (LC-MRM)/MS, to explore the potential utility of PDA071 as a DBM for PIH.
Methods
We tested heat/acid denaturation methods in efforts to purify serum PDA071 and
developed an LC-MRM/MS method allowing for specific quantitation thereof. We measured
serum PDA071 concentrations, and these results were validated including by
three-dimensional (3D) plotting against PDA039 (kininogen-1439–456)/044
(kininogen-1438–456) concentrations, followed by discriminant analysis.
Results
PDA071 was successfully extracted from serum using a heat denaturation method. Optimum
conditions for quantitation via LC-MRM/MS were developed; the assayed serum PDA071
correlated well with the BLOTCHIP® assay values. Although the PDA071 alone did not
significantly differ between patients and controls, 3D plotting of PDA039/044/071
peptide concentrations and construction of a Jackknife classification matrix were
satisfactory in terms of PIH diagnostic precision.
Conclusions
Combination analysis using both PDA071 and PDA039/044 concentrations allowed PIH
diagnostic accuracy to be attained, and our method will be valuable in future
pathophysiological studies of hypertensive disorders of pregnancy. |
---|---|
ISSN: | 0004-5632 1758-1001 |