Automated image quality evaluation of T2‐weighted liver MRI utilizing deep learning architecture

Purpose To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T2‐weighted (T2WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. Materials and Methods We evaluated 522 liver...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of magnetic resonance imaging 2018-03, Vol.47 (3), p.723-728
Hauptverfasser: Esses, Steven J., Lu, Xiaoguang, Zhao, Tiejun, Shanbhogue, Krishna, Dane, Bari, Bruno, Mary, Chandarana, Hersh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To develop and test a deep learning approach named Convolutional Neural Network (CNN) for automated screening of T2‐weighted (T2WI) liver acquisitions for nondiagnostic images, and compare this automated approach to evaluation by two radiologists. Materials and Methods We evaluated 522 liver magnetic resonance imaging (MRI) exams performed at 1.5T and 3T at our institution between November 2014 and May 2016 for CNN training and validation. The CNN consisted of an input layer, convolutional layer, fully connected layer, and output layer. 351 T2WI were anonymized for training. Each case was annotated with a label of being diagnostic or nondiagnostic for detecting lesions and assessing liver morphology. Another independently collected 171 cases were sequestered for a blind test. These 171 T2WI were assessed independently by two radiologists and annotated as being diagnostic or nondiagnostic. These 171 T2WI were presented to the CNN algorithm and image quality (IQ) output of the algorithm was compared to that of two radiologists. Results There was concordance in IQ label between Reader 1 and CNN in 79% of cases and between Reader 2 and CNN in 73%. The sensitivity and the specificity of the CNN algorithm in identifying nondiagnostic IQ was 67% and 81% with respect to Reader 1 and 47% and 80% with respect to Reader 2. The negative predictive value of the algorithm for identifying nondiagnostic IQ was 94% and 86% (relative to Readers 1 and 2). Conclusion We demonstrate a CNN algorithm that yields a high negative predictive value when screening for nondiagnostic T2WI of the liver. Level of Evidence: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:723–728.
ISSN:1053-1807
1522-2586
DOI:10.1002/jmri.25779