Precast Concrete Tunnel Segments with GFRP Reinforcement

AbstractThe possibility of substituting traditional steel reinforcement with glass fiber–reinforced polymer (GFRP) bars in precast concrete tunnel segmental linings is investigated. The use of GFRP reinforcement in concrete tunnel segments results in several advantages mainly related to durability e...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of composites for construction 2017-10, Vol.21 (5)
Hauptverfasser: Spagnuolo, Simone, Meda, Alberto, Rinaldi, Zila, Nanni, Antonio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:AbstractThe possibility of substituting traditional steel reinforcement with glass fiber–reinforced polymer (GFRP) bars in precast concrete tunnel segmental linings is investigated. The use of GFRP reinforcement in concrete tunnel segments results in several advantages mainly related to durability enhancement or when a temporary lining is required. Full-scale bending tests were performed on concrete segments reinforced with GFRP and steel bars in order to compare their structural performance. The results show the effectiveness of the proposed GFRP solution for this type of application. Additionally, a case study is developed presenting provisions for safety checks on GFRP-reinforced tunnel segments.
ISSN:1090-0268
1943-5614