Development of an analysis method for determination of sulfonamides and their five acetylated metabolites in baby foods by ultra-high performance liquid chromatography coupled to high-resolution mass spectrometry (Orbitrap-MS)

•An analytical method is developed and validated for determination of twelve sulfonamides and five acetylated metabolites in baby foods.•The analytes are extracted by using the ASE and the QuEChERS extraction methods.•All analyses are performed by using UHPLC-Orbitrap-MS.•Recovery rates for the anal...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of chromatography. B, Analytical technologies in the biomedical and life sciences Analytical technologies in the biomedical and life sciences, 2017-07, Vol.1057, p.81-91
Hauptverfasser: Konak, Ülgen İ., Certel, Muharrem, Şık, Bülent, Tongur, Timur
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•An analytical method is developed and validated for determination of twelve sulfonamides and five acetylated metabolites in baby foods.•The analytes are extracted by using the ASE and the QuEChERS extraction methods.•All analyses are performed by using UHPLC-Orbitrap-MS.•Recovery rates for the analytes are higher in ASE system.•High selectivity and sensitivity for detection of the analytes at trace levels are provided. A high sensitive and reliable multiresidue method was developed and validated for determination of twelve sulfonamides and five acetylated metabolites in baby foods by using UHPLC-Orbitrap-MS. The sample preparation included two extraction methods as QuEChERS and ASE. The original QuEChERS method was performed, whereas ASE method was optimized to achieve the best recovery for all analytes. UHPLC-Orbitrap-MS parameters were optimized to obtain good retention and separation in LC and high sensitivity and selectivity in MS. The performance of the method was evaluated according to the European Commision Decision 2002/657/EC. Matrix matched calibration curves showed good r2 (≥0.999) and LOQ was ranged from 0.10 to 0.55μg/kg. ASE was significantly more effective for extraction of the analytes (recovery ranged from 75.5 to 96.6% with RSD≤10.1%) than QuEChERS (recovery ranged from 60.9 to 85.9% with RSD≤19.1%). This method was applied to the analysis of 47 different baby foods and no positive samples were found.
ISSN:1570-0232
1873-376X
DOI:10.1016/j.jchromb.2017.04.050