Performance characteristics of the MAMMOCARE PET system based on NEMA standard

In this work, we present the performance characteristics of the MAMMOCARE PET prototype based on an adaptation of the NU 4-2008 NEMA standard. MAMMOCARE is a project under the European Commission's 7th Framework programme to develop a breast biopsy system guided by a dedicated breast PET (dbPET...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of instrumentation 2017-01, Vol.12 (1), p.C01014-C01014
Hauptverfasser: Moliner, L., Correcher, C., Hellingman, D., Alamo, J., Carrilero, V., Orero, A., González, A.J., Benlloch, J.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this work, we present the performance characteristics of the MAMMOCARE PET prototype based on an adaptation of the NU 4-2008 NEMA standard. MAMMOCARE is a project under the European Commission's 7th Framework programme to develop a breast biopsy system guided by a dedicated breast PET (dbPET) images. The PET system is formed by two rings with twelve detector modules each. The transaxial FOV is 170 mm and the axial FOV is 94 mm. The system can separate the detectors up to 60 mm in transaxial plane to allow the biopsy needle entrance. The acquisitions are reconstructed using the LMOS algorithm with tube-of-response (TOR) backprojector, 1 iteration and 16 subsets. The voxel and pixel sizes are (1 x 1 x 1) mm super(3) and (1.6 x 1.6) mm super(2) respectively. The radial resolution measured is 1.62 mm in the center of the FOV and 3.45 mm at 50 mm off the center in the radial direction using the closed configuration. In the open configuration the resolution reaches 1.85 mm and 3.65 mm at center and at 50 mm off-center. The adapted recovery coefficients (ARC) are measured for six hot rods inside a cylindrical phantom with a warm background. The ratio between hot and background regions is 10. The ARC values for the closed configuration are 0.32, 0.77 and 0.96 for the inserts with a diameter of 4.5 mm, 8.3 mm and 25 mm, respectively. These values decrease to 0.16, 0.52 and 0.77 for the open configuration. The sensitivity measured using an energy window of 250 keV-750 keV is 3.6% and 2.5% for the closed and open configurations respectively. The NEC peak is 141 kcps8 MBq and 147 kcps8 MBq for closed and open configurations. The performance characteristics measured with the open ring configuration decreases with respect the closed configuration, however the values remain comparable to other dbPETs.
ISSN:1748-0221
1748-0221
DOI:10.1088/1748-0221/12/01/C01014