Evaluation of Physical and Durability Characteristics of New Headed Glass Fiber–Reinforced Polymer Bars for Concrete Structures

AbstractThis paper presents the results of a collaborative research project between Quebec’s Ministry of Transportation and Ontario’s Ministry of Transportation, which aimed at characterizing a new type of headed glass fiber–reinforced polymer (GFRP) reinforcing bar and evaluating its suitability as...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of composites for construction 2017-04, Vol.21 (2)
Hauptverfasser: Benmokrane, Brahim, Mohamed, Hamdy M, Manalo, Allan, Cousin, Patrice
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:AbstractThis paper presents the results of a collaborative research project between Quebec’s Ministry of Transportation and Ontario’s Ministry of Transportation, which aimed at characterizing a new type of headed glass fiber–reinforced polymer (GFRP) reinforcing bar and evaluating its suitability as internal reinforcement for concrete structures. To achieve these objectives, the project was implemented in three stages: (1) evaluation of the physical and mechanical properties; (2) determination of the pullout behavior in concrete; and (3) characterization of the long-term durability of the headed GFRP bars. A total of 57 specimens embedded in a 200-mm concrete cube were tested with the direct pullout test to investigate the effect of confinement, bar size, concrete compressive strength, and exposure conditions on the pullout behavior of the headed GFRP bars. Simultaneously, microstructural analyses and measurements of the physicochemical and mechanical properties were carried out on conditioned and unconditioned headed GFRP bars. The results show that the materials, geometry, and interface configuration of the head provided very good mechanical interlocking to the GFRP bars. Up to 63 and 53% of the guaranteed tensile strength of the straight GFRP bars were achieved for 15.9- and 19-mm diameter bars with headed ends, respectively. Scanning electron microscopy and differential scanning calorimetry showed no material changes in the head and bars after exposure to alkaline solution and freeze–thaw cycling. Exposure to the alkaline solution under sustained loading had the most detrimental effect, with the bar retaining 79.4% of its pullout strength. The results indicate that the tested headed GFRP bar has suitable mechanical and durability properties for use as reinforcement in concrete bridge components.
ISSN:1090-0268
1943-5614
DOI:10.1061/(ASCE)CC.1943-5614.0000738