Corrosion properties of Sn-0.7Cu solder were investigated in 1 M HCl. The scanning rates used were 0.5, 1.0, 1.5 and 2.0 mVs-1 to study the aggressiveness level of HCl electrolyte in various environment. The morphological, elemental and structural of the samples were compared before and after the co...
Gespeichert in:
Veröffentlicht in: | Materials Science Forum 2017-03, Vol.888, p.394-399 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Corrosion properties of Sn-0.7Cu solder were investigated in 1 M HCl. The scanning rates used were 0.5, 1.0, 1.5 and 2.0 mVs-1 to study the aggressiveness level of HCl electrolyte in various environment. The morphological, elemental and structural of the samples were compared before and after the corrosion. Scan rate 1.0 mVs-1 was chosen as the most optimum scan rate during corrosion analysis. The morphological analysis observed two types of corrosion product which is compacted and loosely-compacted corrosion product after the samples was polarized in 1 M HCl. |
---|---|