Adaptive semiblind background calibration of timing mismatches in a two-channel time-interleaved analog-to-digital converter

This paper introduces an adaptive semiblind background calibration of timing mismatches in a two-channel time-interleaved analog-to-digital converter (TIADC). By injecting a test tone at the frequency of half the overall sampling frequency of TIADC, the timing mismatch between two sub-ADCs can be qu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analog integrated circuits and signal processing 2017-01, Vol.90 (1), p.1-7
Hauptverfasser: Liu, Sujuan, Lv, Ning, Ma, Haixiao, Zhu, Anding
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper introduces an adaptive semiblind background calibration of timing mismatches in a two-channel time-interleaved analog-to-digital converter (TIADC). By injecting a test tone at the frequency of half the overall sampling frequency of TIADC, the timing mismatch between two sub-ADCs can be quickly estimated with great accuracy without affecting the normal operation of the TIADC. The estimated coefficient can then be used in compensation module formed by a fixed structure to calibrate the timing mismatches. Simulation results demonstrate the effectiveness of the proposed estimation and correction technique.
ISSN:0925-1030
1573-1979