The Mushroom: A half‐sky energetic ion and electron detector

We present a time‐of‐flight mass spectrometer design for the measurement of ions in the ~30 keV to 10 MeV range for protons (up to ~40 MeV and ~150 MeV for He and heavy ions, respectively) and ~30 keV to 1 MeV range for electrons, covering half of the sky with 80 apertures. The instrument, known as...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of geophysical research. Space physics 2017-02, Vol.122 (2), p.1513-1530
Hauptverfasser: Hill, M. E., Mitchell, D. G., Andrews, G. B., Cooper, S. A., Gurnee, R. S., Hayes, J. R., Layman, R. S., McNutt, R. L., Nelson, K. S., Parker, C. W., Schlemm, C. E., Stokes, M. R., Begley, S. M., Boyle, M. P., Burgum, J. M., Do, D. H., Dupont, A. R., Gold, R. E., Haggerty, D. K., Hoffer, E. M., Hutcheson, J. C., Jaskulek, S. E., Krimigis, S. M., Liang, S. X., London, S. M., Noble, M. W., Roelof, E. C., Seifert, H., Strohbehn, K., Vandegriff, J. D., Westlake, J. H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We present a time‐of‐flight mass spectrometer design for the measurement of ions in the ~30 keV to 10 MeV range for protons (up to ~40 MeV and ~150 MeV for He and heavy ions, respectively) and ~30 keV to 1 MeV range for electrons, covering half of the sky with 80 apertures. The instrument, known as the “Mushroom,” owing to its shape, solves the field of view problem for magnetospheric and heliospheric missions that employ three‐axis stabilized spacecraft, yet still require extended angular coverage; the Mushroom is also compatible with a spinning spacecraft. The most important new feature of the Mushroom is the method through which uncomplicated electrostatic optics and clean position sensing combine to permit many apertures to fit into a compact, low‐mass sensor head (or wedge), several of which (ideally eight) compose a full instrument. Most of the sensor head's volume is an empty, equipotential region, resulting in the modest 250 g mass of each 10‐aperture wedge. The Mushroom is capable of separating ion species across most of its energy range and angular field of view. For example, separation of the neighboring 3He and 4He isotopes is excellent; the full width at half maximum mass resolution has been measured to be 0.24 amu to 0.32 amu, respectively. Converting this to a Gaussian width σm in mass m, this represents a σm/m mass resolution better than 0.04. This separation is highly desirable for the flight program for which the first Mushroom was built, the Solar Probe Plus mission. More generally, we estimate the mass resolution to be σm/m ≈ 0.1, but this is energy, mass, and angularly dependent. We also discuss the solid‐state detector stack capability, which extends the energy range of protons and helium, with composition, to ~100 MeV. Key Points Anisotropy, pitch angle distributions, and large field of view are important for energetic ion and electron science The “Mushroom” instrument has been developed by JHU/APL to provide needed large FOV and angular resolution The first Mushroom, EPI‐Lo, part of the ISʘIS investigation on Solar Probe Plus, has achieved excellent composition and spatial separation
ISSN:2169-9380
2169-9402
DOI:10.1002/2016JA022614