Prediction of Both Electrical and Mechanical Reverse Remodeling on Acute Electrocardiogram Changes After Cardiac Resynchronization Therapy

Background:The development of both electrical reverse remodeling and mechanical reverse remodeling (ERR+MRR) after cardiac resynchronization therapy (CRT) implantation could reduce the incidence of lethal arrhythmia, hence the prediction of ERR+MRR is clinically important.Methods and Results:Eighty-...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Circulation Journal 2017/08/25, Vol.81(9), pp.1322-1328
Hauptverfasser: Cheng, Chien-Ming, Su, Chieh-Shou, Chou, Pesus, Liao, Ying-Chieh, Wang, Chi-Yen, Zhang, Jian-Rong, Hsieh, Yu-Cheng, Wu, Tsu-Juey, Chen, Yu-Wei, Weng, Chi-Jen, Chang, Keng-Hao, Zhou, Weihua, Hung, Guang-Uei, Huang, Jin-Long, Nakajima, Kenichi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background:The development of both electrical reverse remodeling and mechanical reverse remodeling (ERR+MRR) after cardiac resynchronization therapy (CRT) implantation could reduce the incidence of lethal arrhythmia, hence the prediction of ERR+MRR is clinically important.Methods and Results:Eighty-three patients (54 male; 67±12 years old) with CRT >6 months were enrolled. ERR was defined as baseline intrinsic QRS duration (iQRSd) shortening ≥10 ms in lead II on ECG after CRT, and MRR as improvement in LVEF ≥25% on echocardiography after CRT. Acute ECG changes were measured by comparing the pre-implant and immediate post-implant ECG. Ventricular arrhythmia episodes, including ventricular tachycardia and ventricular fibrillation, detected by the implanted device were recorded. Patients were classified as ERR only (n=12), MRR only (n=23), ERR+MRR (n=26), or non-responder (ERR− & MRR−, n=22). On multivariate regression analysis, difference between baseline intrinsic QRS and paced QRS duration (∆QRSd) >35 ms was a significant predictor of ERR+MRR (sensitivity, 68%; specificity, 64%; AUC, 0.7; P=0.003), and paced QTc >443 ms was a negative predictor of ERR+MRR (sensitivity, 78%; specificity, 60%; AUC, 0.7; P=0.002). On Cox proportional hazard modeling, ERR+MRR may reduce risk of ventricular arrhythma around 70% compared with non-responder (HR, 0.29; 95% CI: 0.13–0.65).Conclusions:Acute ECG changes after CRT were useful predictors of ERR+MRR. ERR+MRR was also a protective factor for ventricular arrhythmia.
ISSN:1346-9843