Electrical superior vena cava isolation using a novel pace-and-ablate technique under diaphragmatic electromyography monitoring
Background Diaphragmatic compound motor action potential (CMAP) amplitude monitoring is a standard technique to anticipate phrenic nerve injury during cryoballoon ablation. Objective The purpose of this study was to evaluate the feasibility of a novel superior vena cava isolation (SVCI) technique us...
Gespeichert in:
Veröffentlicht in: | Heart rhythm 2017-05, Vol.14 (5), p.678-684 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background Diaphragmatic compound motor action potential (CMAP) amplitude monitoring is a standard technique to anticipate phrenic nerve injury during cryoballoon ablation. Objective The purpose of this study was to evaluate the feasibility of a novel superior vena cava isolation (SVCI) technique using simultaneous pacing and ablation through the tip of a single mapping/ablation catheter. Methods Fifty-four patients with atrial fibrillation were included. Radiofrequency energy was delivered point by point uniformly for 20 seconds with a power of 20 W until achieving SVCI. Diaphragmatic CMAPs were obtained from modified surface electrodes by high-output pacing from the mapping/ablation catheter throughout the procedure (pace-and-ablate group). Applications were interrupted if CMAP amplitudes significantly decreased without fluoroscopy. The data were compared with those of the 54 patients undergoing conventional SVCI (conventional group). Results Successful SVCI procedures were achieved in all with a mean of 10.3 ± 2.9 applications. In total, among 559 ablation sites, CMAPs were recorded at 95 (17.0%) with baseline amplitudes of 0.45 ± 0.23 mV. In 10 patients (18.5%), isolation was achieved without any radiofrequency deliveries at CMAP-recorded sites. Among the 95 applications, 6 (6.3%) were interrupted because of CMAP amplitude reductions. At the remaining 88 sites, 20-second radiofrequency applications were delivered without any amplitude decrease (from 0.45 ± 0.21 to 0.46 ± 0.23 mV; P = .885). Phrenic nerve injury occurred in 1 patient in the pace-and-ablate group, which recovered 3 months later, and in 3 conventional group patients, of whom 1 recovered 1 month later ( P = .308). The total procedure time tended to be shorter (14.5 ± 6.3 minutes vs 16.7 ± 9.2 minutes; P = .153) and fluoroscopy time significantly shorter (3.9 ± 3.0 minutes vs 6.7 ± 5.7 minutes, P = .002) in the pace-and-ablate group than in the conventional group. Conclusion A novel and simple pace-and-ablate technique under diaphragmatic electromyography monitoring might be feasible for an electrical SVCI. |
---|---|
ISSN: | 1547-5271 1556-3871 |
DOI: | 10.1016/j.hrthm.2017.01.036 |