Minimum alveolar concentration (MAC) of an inhalant is an indicator of its anesthetic potency. Individuals vary in their sensitivity to anesthetic agents as demonstrated by different individual MAC values. We hypothesized that individual animal sensitivity would be maintained with different inhalant...
Gespeichert in:
Veröffentlicht in: | Veterinary anaesthesia and analgesia 2003-04, Vol.30 (2), p.105-105 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Minimum alveolar concentration (MAC) of an inhalant is an indicator of its anesthetic potency. Individuals vary in their sensitivity to anesthetic agents as demonstrated by different individual MAC values. We hypothesized that individual animal sensitivity would be maintained with different inhalant anesthetics.
As part of separate studies, six female DSH cats, aged 24 ± 2.5 (mean ± SD) months and weighing 3.5 ± 0.3 kg, were studied similarly on three separate occasions over a 12‐month period to determine the MAC of isoflurane (ISO), sevoflurane (SEVO), and desflurane (DES), respectively. In each study, chamber induction was followed by orotracheal intubation, and anesthesia was maintained via a nonrebreathing circuit. ECG, pulse oximetry, Doppler systolic blood pressure, end‐tidal gases, and esophageal temperature were monitored. End‐tidal gases were hand‐sampled from a catheter whose tip lay level with the distal end of the ET tube. Gases were analyzed by Raman spectrometry and, for each agent, the analyzer was calibrated with at least three gas standards. MAC was determined in triplicate using standard tail‐clamp technique. Data were analyzed by two‐way anova followed by Tukey's test and significant differences were found.
Average MACs (%) for ISO, SEVO, and DES were 1.90 ± 0.18, 3.41 ± 0.65, and 10.27 ± 1.06, respectively. Body temperatures, Doppler systolic blood pressure, and SpO2 were recorded at the time of MAC determinations for ISO, SEVO, and DES were 38.3 ± 0.3, 38.6 ± 0.1, 38.3 ± 0.35 °C; 71 ± 8, 75 ± 16, 88 ± 12 mm Hg; 99 ± 1, 99 ± 1, 99 ± 1%, respectively. Both the anesthetic agent and the individual cat had significant effects on MAC (p = 0.0001 and 0.0185, respectively). MAC varied between individuals and cats were consistent in their order of sensitivity to inhalant anesthetics across the three agents.
Within this group of cats, the relationship of individual MAC to the group MAC for each of the three inhalant agents was maintained. This suggests that any individual may be consistently more or less sensitive to a variety of inhalant agents. |
---|---|
ISSN: | 1467-2987 1467-2995 |