Input respiratory impedance in mice: comparison between the flow-based and the wavetube method to perform the forced oscillation technique

Objective and approach: In this study, we estimated the constant phase model (CPM) parameters from the respiratory impedance of male BALB/c mice by performing the forced oscillation technique (FOT) in a control group (n  =  8) and in a murine model of asthma (OVA) (n  =  10). Then, we compared the r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Physiological measurement 2017-06, Vol.38 (6), p.992-1005
Hauptverfasser: Mori, V, Oliveira, M A, Vargas, M H M, da Cunha, A A, de Souza, R G, Pitrez, P M, Moriya, H T
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective and approach: In this study, we estimated the constant phase model (CPM) parameters from the respiratory impedance of male BALB/c mice by performing the forced oscillation technique (FOT) in a control group (n  =  8) and in a murine model of asthma (OVA) (n  =  10). Then, we compared the results obtained by two different methods, using a commercial equipment (flexiVent-flexiWare 7.X; SCIREQ, Montreal, Canada) (FXV) and a wavetube method equipment (Sly et al 2003 J. Appl. Physiol. 94 1460-6) (WVT). We believe that the results from different methods may not be comparable. First, we compared the results performing a two-way analysis of variance (ANOVA) for the resistance, elastance and tissue damping. Main results: We found statistically significant differences in all CPM parameters, except for resistance, when comparing Control and OVA groups. When comparing devices, we found statistically significant differences in resistance, while differences in elastance were not observed. For tissue damping, the results from WVT were observed to be higher than those from FXV. Finally, when comparing the relative variation between the CPM parameters of the Control and OVA groups in both devices, no significant differences were observed for all parameters. Significance: We then conclude that this assessment can compensate the effect of using different cannulas. Furthermore, tissue damping differences between groups can be compensated, since bronchoconstrictors were not used. Therefore, we believe that relative variations in the results between groups can be a comparing parameter when using different equipment without bronchoconstrictor administration.
ISSN:0967-3334
1361-6579
DOI:10.1088/1361-6579/aa6b75